+44 (0)1282 449124

An adaptable area velocity flow meter that can be connected to any data logger or integrate into an established SCADA system.

Q-Flow ultrasonic area velocity flow meter

The Q-Flow 25 is designed to be an adaptable area velocity flow meter that can be connected to any data logger or integrated into an established SCADA system.

It is suitable for use in open channels and partially filled pipes and is ideal for:
Short term flow surveys
Permanent real time monitoring

 

 

how it works

Installed within the open channel, the sensor simultaneously uses ultrasound waves to measure the velocity of the liquid flow and pressure sensing technology to establish depth.

Pre-configured dimensions of the pipe or channel are used to determine the overall volume of flow.

The Q-Flow interface converts the raw data received from the sensor into recognised languages including MODBUS, SDI12 and frequency outputs are all optional.

The Q-Flow 25 interface can be connected to a data logger or integrated directly into a SCADA System via a PLC, giving the user full control.

key features

on board flow claculation

Works in rectangular, circular or trapezoidal pipes. Pulse output can be used for flow proportional sampling.

iN BUILT TEMPERATURE SENSOR

A built-in temperature sensor provides greater accuracy of measurement.

Market leading accuracy

Uses velocity and depth to calculate the overall flow.

COST EFFECTIVE

Where required, the Q-Flow interface can be connected directly to the customers data management system negating the need for additional data loggers, transmitters and controllers.

product specification

VELOCITY SENSOR
Dual piezoelectric elements.

DEPTH SENSOR
Hydrostatic pressure.

INTEGRATED TEMPERATURE COMPENSATION
Titanium diaphragm isolated silicon sensor.

Physical
Sensor cable 10m as standard, up to 20m
if required.

Environmental
Sensor module protection: IP68.
Operating temperature: -20°C to +60°C.

Approvals
Version available with ATEX Zone 0 approval,
Sira 18ATEX2194X and IECEx SIR 18.0049X,
II 1G, Ex ia IIB T4 Ga, Ta = -40°C to +60°C.

PERFORMANCE – Velocity Sensor
Velocity range: 0.03m/s to 4.00m/s
(resolution 1mm/s).
Linearity: ±1%.
Velocity Sensor Accuracy: ±2.5% FS
(±1% in calibrated range 0.05m/s – 2.00m/s).

PERFORMANCE – Depth Sensor
Range: 0.0m to 3.5m (resolution 1.0mm).
Linearity: 0.1% BSL.
Accuracy: ±0.2% FS
(±0.1% in calibrated range 0.03m – 2.00m).

PERFORMANCE – Temperature Sensors
Range: -20°C to +60°C
Resolution:  ±5°C

Version available with ATEX ia Zone 0 approval

downloads

Datasheet

 

Contact Us

Telephone:

+44 (0)1282 449124

Address:
Regent St
Whitewalls Industrial Estate
Colne
Lancashire
BB8 8LJ

Email:

info@detectronic.org

Start your enquiry

If you have a question please start by filling out the form below:

Detectronic © 2018 | HTML Sitemap | Privacy Policy

Web design by Website Design Derby

  • Search ...