Telephone: + 44 (0) 1282 449124

Working in partnership to reduce
flooding
and prevent pollution

A robust, doppler velocity sensor that uses ultrasonic technology to measure wastewater flow with improved accuracy and reliability.

Sumberged Area Velocity Sensor



Key features:

■ Improved accuracy
■ Resists fouling and corrosion
■ Cost effective
■ Versatile installation locations
■ The ORAKEL control unit allows up to 15 additional sensors to be included


Description

The ORAKEL Submerged AV (Area Velocity) Flow Sensor is a robust, doppler velocity sensor that uses  ultrasonic technology to measure wastewater flow with improved accuracy and reliability.

How it works

The Area Velocity Sensor is installed within the open channel.

A bespoke ultrasonic sensor measures a frequency shift from particles within the moving liquid in
order to provide an accurate velocity value.

An integrated pressure sensor is used to measure the depth.

Liquid temperature compensation improves accuracy of the calculated flow.

On-board flow calculation cater for multiple pipe and channel types.

 

Applications

Designed to measure raw sewage, industrial effluents and storm waters. Due to its robust construction, the ORAKEL Submerged AV Flow Sensor can be used in open channels, combined sewers and storm sewers pipes.

A rugged design allows for depth and velocity measurements in the most hazardous of circumstance, whilst the velocity profiled sensor reduces the fouling/ragging risk.

Technical Specificaton

Velocity Sensor – Dual piezoelectric elements.
Depth Sensor – (Hydrostatic pressure.)
Integrated Temperature Compensation – (Titanium diaphragm isolated silicon sensor.)

Physical
Sensor cable 10m as standard, up to 20m if required.

Environmental
Sensor module protection: IP68.
Operating temperature: -20°C to +60°C.

Performance – Velocity Sensor
Velocity range: 0.03m/s to 4.00m/s (resolution 1mm/s).
Linearity: ±1%.
Velocity Sensor Accuracy: ±2.5% FS (±1% in calibrated range 0.05m/s – 2.00m/s).

Performance – Depth Sensor
Range: 0.0m to 6.0m (resolution 1.0mm).
Linearity: 0.1% BSL.
Accuracy: ±0.2% FS (±0.1% in calibrated range 0.03m – 2.00m).

 


Learn More

Download the latest information about the Orakel and Time of Flight Flow Meters.

Submerged AV Flow Meter Datasheet

Orakel Control Unit Datasheet

Watch our Predictive Data Monitoring Video here

Read More

Newsletter Signup

To receive our latest news and announcements please signup to our newsletter.

Regent Street,
Whitewalls Industrial Estate,
Colne, Lancashire,
BB8 8LJ